Test Function
– Winding Resistance stator & Rotor
– Impedance
– Capacitance and Tan Delta of the Winding
– Partial Discharge Stator
Specification
– DC Current 400 Ampere.
– AC Current 800 – 2000 Ampere
Brand & Country of Origin
Omicron CPC-100 – Austria
Test Function
– Winding Resistance stator & Rotor
– Impedance
– Capacitance and Tan Delta of the Winding
– Partial Discharge Stator
Specification
– Cable standard IEC & IEEE
Brand & Country of Origin
Omicron CPC-100 Accessories – Austria
Test Function
– Winding Resistance stator & Rotor
– Impedance
– Capacitance and Tan Delta of the Winding
– Partial Discharge Stator
Specification
– 0 ….12 kV AC
– 100 ….300 mA
– 1pF…..3µF
– 5…..8 mA AC
Brand & Country of Origin
CP TD-1 – Omicron – Austria
Test Function
– Winding Resistance stator & Rotor
– Impedance
– Capacitance and Tan Delta of the Winding
– Partial Discharge Stator
Specification
– Cable standard IEC & IEEE
Brand & Country of Origin
Omicron CP TD-1 Accessories – Austria
Test Function
– Measurement of power factor / tangent delta of large motors and generators
Specification
– Max. voltage 12kV
– Current Compensation up to 1 A
– Capacity Compensation up to 500nF
– Frequency 35 Hz to 85 Hz
Brand & Country of Origin
CP CR500 – Omicron – Austria
Test Function
– Measurement polarization & de-polarization of the winding
– Dielectric Moisture Analysis of the winding
Specification
– Range resolution 200 mA 0.1 pA.
– Input resistance 10 kW
– Accuracy 0.5% ± 1 pF
– Frequency 5 KHz to 50 µHz
– Measurement voltage 200 V Peak range
– Max. continuous output current 50 mA
Brand & Country of Origin
DIRANA – Omicron – Austria
Test Function
– Core and Winding diagnosis
Specification
– Frequency Range 10 Hz to 20 MHz
– Amplitude 2.83 Vpp = 1 Vrms at 50 Ω load
– DC Power Supply DC 10 V to 24 V / 10 W
– AC Power Supply AC 100V to 240 V / 50 to 60 Hz
– Dinamics Range > 120 dB
– Accuracy < 0.1 dB (down to -50 dB) and
Brand & Country of Origin
Omicron Franeo 800 – Austria
Test Function
-Test and Measure Insulation Resistance & Polarization Index
Specification
– Test Voltage up to 10 kV
– CAT III 1000V, CAT IV 600V
– Automatic calculation of Dielectric Absorption (DAR)
– Automatic calculation of Polarization Index (PI)
– Resistance measurement up to 2TΩ
Brand & Country of Origin
Fluke 1555 – USA
Test Function
– Hi-pot test DC up to 80 kV
– Hi-pot DC for Generator
– Hi-pot DC for Motor
Specification
– DC Voltage 0 – 80 kV
– Output Current 0.8 mA @ 80 kV , and 1.5 mA @ 70 kV
– Short Circuit 20mA
– Current measuring range 20 nA to 1 µA / 10 µA / 100 µA / 1 mA / 10 mA / 100 mA
– Max Discharge 8000 J at 1 Discharge / 15 Min (ambient temperature 20oC)
Brand & Country of Origin
Baur PGK 80 E – Germany
Test Function
– Bus Controller
Specification
–USB 2.0 Type B
– Fiber Optical Network
– 600 series: 2ST connector; suitable for MPD600
Brand & Country of Origin
MCU 502 – Omicron – Austria
Test Function
– Off-line and On-line Partial Discharge Transformer
Specification
– Frequency 0 to 32 MHz
– Frequendy domain bandwith 300 kHz, 650 kHz, 1 MHz, 1.5 mHz
Brand & Country of Origin
MPD 600 – Omicron – Austria
Test Function
– Used to injected a defined charge into and verivy the mesurement circuit.
Specification
–Pulse Repettion Frequency up to 300 Hz
– Pulse Rise Time < 4ns
Brand & Country of Origin
CAL 542 – Omicron – Austria
Test Function
– Used to the high-voltage test object
Specification
–Voltage 12 to 24 kV
– Capacitor Nominal up to 1.2 nF
Brand & Country of Origin
Coupling Capacitor – Omicron – Austria
Test Function
– Measurement impedance unit for partial discherge
Specification
–Max. Currents 0.5 A 1.2A/2A or
– Frequency Range (PD Output) 20 kHz to 5 MHz
– Low-arm capacitance 30 µF (for 2A or 1.2 A)
– Input terminal 2 x 4mm terminal – 1 x GND
– Output Connector 2 x BNC (PD & V) & 1 x BNC (TTL Signal)
Brand & Country of Origin
CPL 542A – Omicron – Austria
Test Function
– Transport Case – Hard Case Standard for MPD Set Unit
Specification
-Transport Cases Omicron – Austria
Test Function
–Vibration Test & Diagnosis for Motor, Pump, Generator, Compressor
Specification
– Rotation Speed 200 to 12.000 rpm
– Diagnosis for unbalance, looseness, misalignment and bearing failures
– Sampling 51.2 Hz
– Amplitude Units: in/sec, mm/sec, Vdb
– Acceleration: g, m/sec²
– Velocity: in/sec, mm/sec
– Displacement: mils, mm
Brand & Country of Origin
Fluke 810 – USA
Test Function
– Pump alignment
– Motor Alignment
– Fan Alignment
– Generator Alignment
Specification
– Laser: 650 nm class II diode laser
– Measurement Distance: up to 10 m (33 feet)
– Detector Length 30 mm (1.2 in)
– Detector Resolution: 1 µm (0.04 mils)
Brand & Country of Origin
Fiture Laser NXA Pro – Sweden
Test Function
– Vibration Tester for Pump, Motor, Fan, Generator, etc.
Specification
– Low frequency range: 10 Hz to 1,000 Hz
– High frequency range 4,000 Hz to 20,000 Hz
– Vibration Limit: 50 g peak (100 g peak-peak)
– Acceleration: g, m/sec²
– Velocity: in/sec, mm/sec
– Displacement: mils, mm
Brand & Country of Origin
Fluke 805 -USA
Test Function
– Tachometer Tester
Specification
– Detection Range 50 mm to 500 mm
– Reflection detection indicator: Flashing red LED built into Hold key
– Sampling period: 62.5 ms to 2 s
Brand & Country of Origin
Hioki FT3406 – Japan